🏗️ DETAILED NOTES
1️⃣ Introduction
Roof fall is one of the most common and deadly hazards in underground coal mines. According to DGMS accident statistics (2014), a significant percentage of fatalities were caused by collapse of roof or sides, primarily due to poor roof support, inadequate examination, and failure to follow support plans.
2️⃣ DGMS Findings (2014)
Major Cause: Insufficient or delayed support installation.
Contributing Factors: Over-extraction and wide spans between supports; Poor quality of timber or props; Water seepage and weak roof strata; Inadequate supervision or early withdrawal of support.
Affected Areas: Bord & pillar workings, depillaring panels, junctions, and inclines.
DGMS Observation: 90% of roof fall accidents were preventable through proper roof monitoring and timely support installation.
3️⃣ Legal Provisions
| Regulation / Rule | Description | 
|---|---|
| CMR 2017 – Reg. 99 | Support of working places | 
| Reg. 100 | Withdrawal of supports | 
| Reg. 101 | Systematic Support Rules (SSR) | 
| Reg. 102 | Precautions during depillaring | 
| Reg. 106 | Duties of competent persons | 
| Mines Act, 1952 – Sec. 23 | Duties related to mine safety | 
4️⃣ Causes of Roof Fall
- Non-installation or removal of support before time.
 - Delay in setting supports near the working face.
 - Poor condition of timber or bolts.
 - Wide gallery width or overhanging roof.
 - Non-adherence to systematic support rule (SSR).
 - Lack of supervision during loading or depillaring.
 
5️⃣ Preventive Measures
- Proper Support Installation: Immediate setting of props/bolts within 1.5 m of the face.
 - Systematic Support Rules (SSR): Follow approved SSR for each seam.
 - Strata Monitoring: Use tell-tales, extensometers, and convergence indicators.
 - Adequate Lighting: Ensure illumination for roof visibility.
 - Training: Educate workers on early signs of roof movement.
 - Supervision: Supervisory presence during support installation and removal.
 - Roof Bolting: Mechanized bolting for improved safety.
 
6️⃣ DGMS Recommendations
DGMS advised all mine managers to conduct special safety drives focusing on roof support practices. A review of SSR was mandated, especially in depillaring panels. All future roof monitoring must include instrumented observations and risk-based classification of areas. DGMS Circular No. 02/2016 on roof fall prevention reiterated these standards.
7️⃣ Lessons Learned
| Issue Identified | Corrective Action | 
|---|---|
| Delayed support installation | Install supports immediately after cutting | 
| Poor supervision | Ensure competent person presence | 
| Weak strata | Apply grouted bolts & steel girders | 
| Non-adherence to SSR | Strict compliance and review | 
| Untrained labor | Conduct practical training sessions | 
⚡ QUICK ONE-LINERS
- Roof fall = top cause of fatalities in underground mines.
 - Reg. 99–102 of CMR 2017 govern roof support.
 - DGMS Circular 02/2016 covers roof safety. (Note: Original text mentioned 06/2014 for SSR)
 - Supports must be within 1.5 m of face.
 - Telltales used for roof movement monitoring.
 - Depillaring areas highly prone to roof falls.
 - SSR must be mine-specific and DGMS-approved.
 - Weak roof → use steel supports or bolts.
 - Roof fall risk increases with poor supervision.
 - Continuous monitoring = key to prevention.
 
🧠 DESCRIPTIVE QUESTION & ANSWER
Q. Discuss the DGMS guidelines and lessons learned from the fatal accident involving four persons due to roof fall in an underground coal mine.
Answer:
                        A fatal accident occurred in an underground coal mine where four persons lost their lives due to a sudden fall of roof during depillaring operations. Investigation by DGMS revealed that roof support installation was inadequate, and the Systematic Support Rule (SSR) was not followed strictly. The roof strata were weak, and tell-tales were not installed for early detection of movement.
Key Findings: Supports were not installed immediately after extraction; Roof inspection by the competent person was not thorough; Supervision during shift change was poor.
Regulations Referenced: CMR 2017, Reg. 99–102 (Support, SSR, Withdrawal); DGMS Circular 02/2016 (Roof fall control measures).
Preventive Measures: Follow SSR strictly; Use tell-tales in all depillaring panels; No work under unsupported roof; Provide roof bolting in systematic grid pattern; Regular roof safety training.
Conclusion: Strict adherence to support regulations and effective supervision can prevent recurrence of such tragic accidents. Every miner must understand that roof safety is life safety.
🎯 25 MCQs – Roof Fall Accident & DGMS Safety Rules
Q1. Which regulation of CMR 2017 deals with roof support?
Q2. SSR stands for:
Q3. Tell-tales are used for:
Q4. Fatal accident involved how many persons?
Q5. Roof fall commonly occurs during:
Q6. DGMS circular for roof fall prevention:
Q7. Roof support must be:
Q8. Minimum roof support inspection frequency:
Q9. Unsupported roof area is:
Q10. Withdrawal of supports requires:
Q11. Roof fall hazard mainly due to:
Q12. Roof bolting spacing depends on:
Q13. SSR approval authority:
Q14. Roof fall accident reporting under:
Q15. Roof monitoring device:
Q16. Overman responsibility:
Q17. Roof fall leads to:
Q18. Depillaring involves:
Q19. DGMS stresses on:
Q20. Roof fall mostly occurs in:
Q21. Roof bolt type used:
Q22. Support withdrawal order given by:
Q23. Roof fall hazard prevented by:
Q24. DGMS mandates tell-tale frequency (typical guideline):
Q25. Main cause of roof fall fatalities:
🔗 INTERNAL LINKING SUGGESTIONS
| Related Topic | Read More On... | 
|---|---|
| Strata Control | Strata Monitoring in Longwall Workings | 
| Safety Management | Integrated Safety Management Plan (SMP) | 
| DGMS Circulars | DGMS Tech SOMA Circular No. 03 of 2024 | 
| Accident Investigation | Accident Investigation & Legal Framework | 
🚨 Prevent Roof Fall Fatalities – Learn with DGMS Experts!
Join Online Mining Exam – India’s 1st Online Mining Academy for:
- Detailed DGMS Roof Safety Notes
 - Real Accident Case Studies
 - 5000+ Practice MCQs for DGMS Exams
 
📞 Call/WhatsApp: 9971114020