🧾 DETAILED NOTES
1️⃣ Introduction
Proper lighting is vital for safe and efficient mining operations, both on the surface and underground. Inadequate or unsafe lighting systems have caused accidents due to poor visibility, glare, or electrical sparks in hazardous areas. Therefore, DGMS mandates approval of all types of lighting fixtures, fittings, and signal lights used in mines, including those on HEMMs (Heavy Earth Moving Machinery) and other mobile equipment.
2️⃣ DGMS Safety Concern
DGMS emphasizes that all lights, fixtures, and electrical systems used in gassy underground and oil/gas fields must be flameproof (FLP) or intrinsically safe (IS) to prevent ignition of flammable gases. For surface mines, lighting systems must comply with electrical safety and illumination standards to prevent glare and electrical hazards.
3️⃣ Legal Framework
| Reference | Description |
|---|---|
| The Mines Act, 1952 – Sec. 23 | Employer’s responsibility for worker safety. |
| CMR 2017 – Regulation 131 & 132 | Electrical lighting and illumination standards. |
| DGMS Circular (Tech.) No. 08/2019 | Guidelines for approval of lighting systems in mines. |
| DGMS Circular (Elec.) No. 04/2014 | Electrical safety in HEMM lighting and signaling. |
| IS: 2148 & IS/IEC 60079-1 | Standards for flameproof enclosures. |
4️⃣ Objective
- Ensure all lighting fixtures in mines meet safety standards.
- Prevent ignition hazards in gassy or oil mines.
- Maintain adequate visibility for workers.
- Reduce glare, shadows, and accidents during night operations.
- Regulate approval process through DGMS testing and certification.
5️⃣ Types of Lighting Systems in Mines
| Type | Description | Application |
|---|---|---|
| Fixed Lighting | Installed on poles, conveyors, workshops. | Surface mines, plants. |
| Mobile Lighting | Mounted on HEMMs, dumpers, shovels. | Opencast working zones. |
| Portable Lamps | Rechargeable hand lamps or cap lamps. | Underground workings. |
| Signal & Indicator Lights | On machinery or haul roads. | HEMMs, plants. |
| Explosion-Proof Lights | Flameproof fittings in gas zones. | Underground coal/oil mines. |
6️⃣ DGMS Approval Requirements
All lighting systems must be approved by DGMS after compliance testing under relevant BIS/IEC standards.
⚙️ Approval Process:
- Manufacturer submits application to DGMS (Electrical Division) with specifications.
- Sample sent to Testing Authority (e.g., CIMFR, CMERI, ERTL, CPRI).
- Testing includes: Insulation resistance, Flameproof/thermal endurance, IP protection, vibration, and illumination/glare tests.
- Test report reviewed by DGMS.
- Upon compliance, DGMS issues Type Approval Certificate.
7️⃣ Lighting on Board HEMMs and Machinery
- All headlights, tail lights, and signal lights on HEMMs must be DGMS-approved.
- Lights must withstand vibration, dust, and moisture.
- Flashing amber lights required for moving equipment.
- Brake and turn indicator lights must be visible from 50 meters.
- Wiring must be properly insulated and secured.
8️⃣ Lighting in Underground Mines
- Use intrinsically safe (IS) or flameproof (FLP) lights only.
- Voltage level must not exceed 110 V in gassy zones.
- Lamps must meet IS/IEC 60079-1 standards.
- Cap lamps must be IS-approved and regularly maintained.
9️⃣ Minimum Illumination Standards (as per DGMS)
| Location | Minimum Lux Level |
|---|---|
| Underground haulage road | 5 lux |
| Coal face | 10 lux |
| Opencast haul road | 15 lux |
| Workshops / plants | 50 lux |
| Office / Control room | 100 lux |
⚙️ QUICK ONE-LINERS (Revision Points)
- DGMS Circular 08/2019 → Lighting approval guidelines.
- Regulation 131 (CMR 2017) → Mine lighting provisions.
- HEMM lights must be DGMS-approved.
- IS 2148 → Flameproof standard.
- Intrinsically safe lights used underground.
- Voltage ≤ 110 V in gassy zones.
- Headlights visible ≥ 50 m.
- LED lights encouraged by DGMS.
- Lux standard: 10–50 lux typical for workings.
- Testing labs: CIMFR, CPRI, ERTL.
🧩 DESCRIPTIVE MODEL QUESTION & ANSWER
Q. Explain the DGMS procedure for approval and safe use of lighting systems in mines.
Answer:
DGMS requires that all lighting fixtures and systems used in mines (HEMMs, plants, underground) be tested and approved. The manufacturer must submit samples to DGMS-approved labs (like CIMFR/CPRI) for testing against standards like IS 2148 (Flameproof) or IS/IEC 60079-1 (Intrinsically Safe). After reviewing the test report, DGMS issues a Type Approval Certificate. For safe use, mine management must ensure correct installation (e.g., voltage < 110V in gassy zones), maintain illumination levels as per Reg. 131, and conduct regular inspections.
🧮 25 DGMS-Based MCQs (5 Options Each)
Q1. DGMS Circular for lighting approval:
Q2. Flameproof standard for lighting fixtures:
Q3. Voltage limit in underground gassy zone:
Q4. Intrinsically safe standard:
Q5. Testing lab for lighting systems:
Q6. HEMM lights must be:
Q7. Minimum illumination at coal face:
Q8. Regulation for illumination:
Q9. Signal light color for moving HEMM:
Q10. Lux level for workshop:
Q11. Cap lamps used in:
Q12. DGMS approval ensures:
Q13. Fixed lighting used in:
Q14. DGMS Circular 04/2014 covers:
Q15. BIS standard for cables:
Q16. Lux level on opencast haul road:
Q17. Lighting failure risk:
Q18. Oil mines use:
Q19. Light inspection frequency:
Q20. DGMS approval certificate validity:
Q21. Cap lamp voltage:
Q22. Flameproof light used in:
Q23. Portable lights must be:
Q24. Illumination measured in:
Q25. Main purpose of DGMS approval:
🔗 INTERNAL LINKS
| Related Topic | Read More On... |
|---|---|
| Electrical Safety | Electrical Safety, Accident Investigation & Legal Framework |
| HEMM Safety | Safety Features in Crawler/Tyre Mounted Machinery |
| Opencast Lighting | Standards of Illumination in Opencast Mines |
| DGMS Circulars | DGMS Training Syllabus for Electrical Engineers |
💡 Light Up Mines Safely – Learn DGMS Lighting Approval Rules!
Join Online Mining Exam (OME) – India’s 1st Online Mining Academy for:
- Lighting System Approval Notes
- 25 DGMS MCQs with Answers
- Real Testing & Circular Insights
🌐 Visit: www.onlineminingexam.com