DGMS Factory Inspection & Audit Checklist – Appendix XIX Explained | DGMS Notes


🏭 DGMS Factory Inspection & Audit Checklist – Appendix XIX 

Factory inspection is a mandatory step before DGMS grants approval for:
  • Flameproof equipment
  • Intrinsically safe equipment
  • Gas detectors
  • Electrical machinery
  • PPE & safety devices
  • Importer-based equipment
DGMS verifies whether the manufacturer’s production system matches the approved design, standards & safety requirements. Appendix XIX of the DGMS Approval Policy explains exact factory audit points, which we decode below in simple OME style.

🔹 1. Purpose of DGMS Factory Inspection DGMS conducts factory audits to ensure:

✔ Correct manufacturing practices
✔ Consistency with technical drawings
✔ Proper quality & safety checks
✔ Calibration of testing equipment
✔ Good traceability system
✔ No unauthorized modification
✔ Adequate test facilities
✔ Controlled production environment

🔹 2. When Is DGMS Factory Audit Mandatory?

A factory audit is needed in: 

1) New DGMS Approval Before issuing approval for the first time.

2) Renewal (Every 3 Years) To verify consistent quality.

3) Suspension / Complaint Cases On receiving field complaints.

4) Imported Equipment (IAR Audit) DGMS inspects service facilities of the Indian Authorized Representative.

🔹 3. Components of DGMS Factory Audit (Appendix XIX) 

 A DGMS audit covers 8 major sections:

⭐ 1) Quality Management System (QMS) DGMS checks:
  • ISO 9001 compliance
  • QMS manual
  • Quality policy
  • Organizational structure
  • Document control
  • Corrective & preventive action (CAPA) system
All processes must be documented.

⭐ 2) Manufacturing Infrastructure DGMS verifies:
  • Machinery & tools
  • Flameproof machining facilities
  • CNC machines
  • Winding machines
  • PCB assembly line (for IS equipment)
  • Painting/finishing
  • Assembly line layout
Equipment must match the approved drawings.

⭐ 3) Flameproof (FLP) Production Facilities DGMS checks:
  • Flamepath machining capability
  • Surface finish (Ra ≤ 6.3 μm)
  • Dimensional gauges
  • Torque-controlled tightening tools
  • Thread gauges
  • Air pressure test setups
Over 60% rejections occur due to poor flamepath machining.

⭐ 4) Testing Infrastructure Factories must have: For FLP Equipment:
  • Flamepath gauges
  • Pressure test chamber
  • Vernier/micrometers
  • Temperature meters
  • Gap measuring tools
For IS Equipment:
  • Oscilloscopes
  • Calibrated multimeters
  • Component testers
  • Thermal chamber
General Tests:
  • HV tester
  • IP test setup
  • Earth resistance meter

⭐ 5) Calibration System DGMS verifies:
  • Calibration register
  • Traceability to NABL/NIST
  • Periodic calibration
  • Stickers on equipment
Uncalibrated testing equipment = automatic rejection.

⭐ 6) Material Traceability & Stores Every part must be traceable to:
  • Batch number
  • Supplier certificate
  • Material grade
  • Inspection report
  • Raw material acceptance
DGMS checks whether materials used = material in technical drawings.

⭐ 7) Quality Control Records Factory must maintain:
  • Incoming inspection reports
  • In-process inspection
  • Routine test results
  • Final inspection checklist
  • Non-conformance records (NCR)
  • CAPA reports
DGMS ensures all products are batch-tested before dispatch.

⭐ 8) Compliance with Approved Drawings The most important part: 

❌ ANY deviation from drawing = Rejection
Examples:
  • Flamepath dimensions changed
  • Material changed
  • PCB design modified
  • Thickness variations
  • Fastener grade change
Only DGMS-approved drawings must be in production.

🔹 4. DGMS Factory Audit Procedure

DGMS Issues Audit Notice ↓ Manufacturer Prepares Documents ↓ DGMS Inspection Team Visits Factory ↓ Verification of QMS, Testing & Production ↓ Check Against Appendix XIX Checklist ↓ Non-Conformity Report (if any) ↓ Corrective Action by Manufacturer ↓ Audit Clearance Issued If non-conformity is not resolved → DGMS rejects/withdraws approval.

🔹 5. Documents Required During DGMS Factory Audit
  • ISO 9001 certificate
  • QAR/QAN
  • Calibration certificates
  • Raw material test certificates
  • Purchase records
  • Test equipment list
  • Batch test reports
  • TG (Technical File)
  • Flamepath measurement reports
  • Employee qualification/skill matrix

🔹 6. Common Reasons for Audit Failure

❌ Flamepath machining errors
❌ Lack of calibration
❌ No batch test reports
❌ Unauthorized design changes
❌ Poor traceability system
❌ QMS not updated
❌ Production vs. drawing mismatch
❌ Fabricated test reports
❌ Non-certified raw materials

🔹 7. How to Prepare for DGMS Factory Audit (Checklist)

✔ Ensure ALL drawings are DGMS approved

✔ Maintain proper calibration records

✔ Keep dedicated gauges for flamepaths

✔ Maintain raw material certification

✔ Ensure batch-wise QC records

✔ Provide traceability of every component

✔ Train QC inspectors & operators

✔ Keep production as per QMS manual

🔥 25 MCQs (DGMS Pattern) with Answers

1) Factory audit requirement comes from — a) Appendix VI
b) Appendix XIX
c) CMR 2017
d) Indian Standards
e) None
Ans: b

2) DGMS audit checks —

a) GST
b) HR files
c) Manufacturing & testing
d) Parking area
e) None
Ans: c

3) Calibration records must be —

a) Optional
b) Mandatory
c) Rare
d) Weekly only
e) None
Ans: b

4) ISO required for DGMS approval —

a) ISO 22000
b) ISO 27001
c) ISO 9001
d) ISO 45001
e) None
Ans: c

5) Ex equipment drawings must be —

a) Verbal
b) DGMS approved
c) Hand-sketched
d) Suggested only
e) None
Ans: b

6) Flamepath finish should be —

a) Rough
b) Painted
c) Smooth (Ra ≤ 6.3 μm)
d) Cracked
e) None
Ans: c

7) Unauthorized design change leads to —

a) Discount
b) Promotion
c) Rejection/withdrawal
d) Team party
e) None
Ans: c

8) Test equipment must be —

a) Random
b) Calibrated
c) Broken
d) Cheap
e) None
Ans: b

9) QAR stands for —

a) Quality Alteration Reference
b) Quality Assurance Report
c) Quantity Audit Result
d) Quota Adjustment Rule
Ans: b

10) Factory audit ensures —

a) Festivals
b) Employee leave
c) Production matches approved drawings
d) Salaries
e) None
Ans: c

11) PCB changes need —

a) No permission
b) Fresh DGMS approval
c) Manager approval
d) Storekeeper permission
e) None
Ans: b

12) Flamepath measured using —

a) Tape
b) Rope
c) Feeler gauges/micrometers
d) Colour card
e) None
Ans: c

13) Raw material certificate ensures —

a) Colour
b) Smell
c) Weight
d) Correct grade used
e) None
Ans: d

14) Field trial data required for —

a) First approval
b) Renewal
c) GST audit
d) Factory layout
e) None
Ans: b

15) DGMS checks QMS —

a) Monthly
b) Sometimes
c) During audit
d) Every day
Ans: c

16) Batch testing is —

a) Optional
b) Mandatory
c) Not needed
d) Temporary
Ans: b

17) Flameproof test facility required for —

a) Footwear
b) Ex-d equipment
c) Gas cylinders
d) Uniforms
Ans: b

18) Test reports must be —

a) Editable
b) Original & signed
c) Only photocopies
d) Verbal
Ans: b

19) Factory audit fails if —

a) Machines working
b) Drawings correct
c) Calibration outdated
d) QMS updated
Ans: c

20) Production deviation from drawing —

a) Allowed
b) Forbidden
c) Encouraged
d) Free
Ans: b

21) Material traceability used for —

a) Decoration
b) Music
c) Fun
d) Tracking materials used
Ans: d

22) Testing infrastructure includes —

a) Toy tools
b) HV tester, gauges, pressure test
c) Paint brushes
d) Fans
Ans: b

23) Factory layout part of —

a) Finance
b) QMS documentation
c) Housekeeping
d) Labour law
Ans: b

24) DGMS audit team looks for —

a) Company profit
b) Employee holidays
c) Compliance & safety
d) Office chairs
Ans: c

25) Purpose of DGMS factory audit —

a) Increase sales
b) Reduce workers
c) Ensure safe & compliant manufacturing
d) Save electricity
Ans: c

🔚 Conclusion 

DGMS Factory Inspection (Appendix XIX) ensures that equipment is manufactured with proper quality, safety, calibration & control.
A high-quality audit system ensures:
  • Zero design deviation
  • Authentic testing
  • Reliable performance
  • Safe use in gassy mines
Every manufacturer must follow Appendix XIX to avoid rejection, suspension or withdrawal of DGMS approval.

🚀 Download DGMS Factory Audit Notes at OnlineMiningExam.com
📝 Practice 10,000+ DGMS MCQs
🔔 Join OME Telegram Channel for daily DGMS updates


{{ONLINEMININGEXAM.COM}}
India's 1st Online Mining Academy Prepare for DGMS 1st Class & 2nd Class Mining Manager......


OUR COURSES View More

/* Banner container */ #omxBanner { position: fixed; left: 50%; bottom: -120px; /* hidden initially */ transform: translateX(-50%); width: min(980px, calc(100% - 20px)); max-width: 980px; background: linear-gradient(90deg,#0f172a,#0b84ff); color: #fff; border-radius: 12px 12px 8px 8px; padding: 11px 14px; /* reduced (80%) */ box-shadow: 0 12px 30px rgba(3,10,30,0.45); display: flex; gap: 10px; align-items: center; z-index: 2000; transition: bottom 450ms cubic-bezier(.2,.9,.3,1), transform 250ms; font-family: system-ui, -apple-system, "Segoe UI", Roboto, "Helvetica Neue", Arial; } /* Show class slides banner up */ #omxBanner.show { bottom: 20px; } /* Left: icon / logo */ #omxBanner .left { flex: 0 0 51px; /* 80% of 64px */ height: 51px; border-radius: 6px; background: linear-gradient(135deg,#00d4ff,#0077ff); display:flex; align-items:center; justify-content:center; font-weight:700; color:#002; font-size:16px; /* reduced */ } /* Middle: text */ #omxBanner .center { flex: 1 1 auto; min-width: 0; } #omxBanner .center h4 { margin: 0 0 3px 0; font-size: 13px; /* reduced */ line-height: 1.1; letter-spacing: 0.2px; } #omxBanner .center p { margin: 0; font-size: 11px; /* reduced */ opacity: 0.95; } /* Right: CTA & close */ #omxBanner .right { display:flex; gap:6px; align-items:center; } #omxBanner .cta { background: linear-gradient(90deg,#ffb703,#fb8500); color: #07122a; border: none; padding: 8px 11px; /* reduced */ border-radius: 6px; font-weight: 700; cursor: pointer; text-decoration: none; font-size: 12px; /* reduced */ box-shadow: 0 6px 14px rgba(251,133,0,0.22); } #omxBanner .cta:active { transform: translateY(1px); } #omxBanner .closeBtn { background: transparent; border: none; color: rgba(255,255,255,0.9); font-size: 16px; /* reduced */ cursor: pointer; padding: 4px; line-height:1; } /* Mobile tweaks */ @media (max-width:600px) { #omxBanner { flex-direction: column; gap:6px; align-items:flex-start; padding:9px; bottom: 10px; width: calc(100% - 18px); left: 50%; transform: translateX(-50%); } #omxBanner .left { display:none; } #omxBanner .right { width:100%; justify-content: space-between; } #omxBanner .cta { width:48%; text-align:center; padding:8px 6px; font-size:11px; } }